Testimonium | NEAOCDC-24075025002-E101 | Animadverte |
Dimensio (W*D*H) unitas (mm) | 830mm*830mm*1850mm | |
Machinam ostentationem | 7 pollicis tactus velum, resolutio: 1024×600 | |
Pondus | 390kg | |
Incurrens funem longitudinem | 7m | Vestibulum longitudinem |
DC output | ||
Maximilianus.Potestas | 240kW | |
DC Output voltage range | 200-750V | |
DC output current range | 0-250A | |
Max.output potentia unius gun | 180kW | Dual-gun simultaneus output sustinet potentiam intelligentem dynamicam distributionem |
Constans potentia output voltage range | 330~ 750V | |
Current acquisition accuracy | ≥30A.non plus quam ± I% <30A.non plus quam ± 0.3A * | |
Acquisitio intentione accurate | ≤±0.5%FSR(fullscale) | |
intentione laniatus coefficientis | Valorem efficax: non plus±0.5% Apicem valorem: non plus±1% | |
Output current responsio tempus | ≥20A/s | |
Esimpliciter current et unbalance | <Rated onus vena*5% | |
Watt hora metriaccurate rating | 1.0 | |
Diver meter accurate rating | 0.2 | |
IP rating | IP 54 | |
AC input | ||
AC Input voltage | AC380V±15% | |
Input Power Factor | ≥0.99.L%<Po/Pn≤100%≥0.96.20%≤Po/Pn≤L%. | A-genus armorum |
Totalis vena harmonica | ≤5% | Cum XX%~50% potentiae aestimatae, tota contenta currenti harmonica non plus quam 12% est. |
Indicatores conventionales | ||
Consummatio virtutis standby | ≤100W | |
Initus fluere current | ≤CX% of rated initus current | |
Output Overshoot Current | ≤20A | |
Data sampling tempore | ≤500ms/1s | |
Test valorem update tempore | ≤1000ms | Exceptio acta localiter cum 1000 monumentis reponuntur |
Crimen initium temporis | ≤30s | A tempore incipit incurrentis machina usque ad statum tempus in vehiculo perveniat |
Potestas auxiliaris voltage | 12V/24V±0.6V | 24V potentia copia est libitum |
Auxilia virtutis copia rated current | 10A | |
exosculatio interface | Mobile Payment / IC Tollenone pluma | IC Tollenone pluma est libitum |
Praesidium auxilium | Over/under-voltage, over-current, overload, short circuit protection, reverse connexion protection, communication interruption protection, access control protectio, inundatio protectio, etc. | |
Interface | RS485/RS232, CAN, Ethernet | |
Communicatio externa interface | Ethernet | GPRS / 4G est libitum |
Refrigerationem modus | Coactus aeris refrigerationem | |
Apicem totius machinae efficientiam | ≥95.2% | |
Electrostatica missionis immunitas | 3 | |
RF campum electromagneticum radiorum immunitatis | 3 | |
Electrical ieiunium fluxum pulsus coetus immunitas | 3 | |
Surge immunitatem | 3 | |
Certification | Typus test | |
Enviornmental Peformance | ||
opus temperatus | -25~55°C | |
Repono temperatus | -40~70°C | |
opus humiditas | 0~95% RH | Wsine condensatione |
opus habitus | ≤2000m | |
Reliability and Designed Service Life | ||
Mediocris culpa temporis MTBF | ≥26280h | |
Disposito servitium vitae | ≥10annos |